Upgrade a Sensor
If you are not using the latest version of the sensor, use the following instructions to upgrade your sensor.
If you downloaded the sensor image (ISO) from Cisco XDR (Administration > On-Premises Appliances > Sensors > Installation), use Ubuntu to upgrade your sensor.
-
Review the current sensor version. For details, see Verify Your Sensor Version.
-
Log in to Ubuntu system as an administrator.
-
Stop the service and back up the existing configuration:
-
At the command prompt, enter
sudo systemctl stop obsrvbl-ona.serviceand press Enter to stop the service. -
Enter
sudo cp /opt/obsrvbl-ona/config.auto ~/config.autoand press Enter. -
Enter
sudo cp /opt/obsrvbl-ona/config.local ~/config.localand press Enter.
-
-
Download the new package:
-
Enter
rm -f ona-serviceand press Enter. -
Enter
sudo wget https://assets-production.obsrvbl.com/ona-packages/obsrvbl-ona/v5.1.3/ona-service_UbuntuNoble_amd64.deband press Enter.
-
-
Remove the old package and install the new one:
-
Enter
sudo apt remove --purge ona-serviceand press Enter. -
Enter
sudo apt install ./ona-service_UbuntuNoble_amd64.deband press Enter.
-
-
Restore your backup configuration:
-
Enter
sudo cp ~/config.auto /opt/obsrvbl-ona/config.autoand press Enter. -
Enter
sudo cp ~/config.local /opt/obsrvbl-ona/config.localand press Enter. -
Enter
sudo chown obsrvbl_ona:obsrvbl_ona /opt/obsrvbl-ona/config.auto /opt/obsrvbl-ona/config.localand press Enter.
-
-
Restart the system:
-
Enter
sudo systemctl restart obsrvbl-ona.serviceand press Enter.
-
-
Verify the update:
-
Follow the instructions in Confirm a Sensor Connection and confirm the sensor is shown in the list and receiving data.
-
Follow the instructions in Verify Your Sensor Version to confirm that the sensor version is updated.
-